一、產(chǎn)品簡介:
是根據(jù)標(biāo)準(zhǔn)GB8810-2005《硬質(zhì)泡沫塑料吸水率檢測》設(shè)計(jì)制造。具有使用簡單、**度高的特點(diǎn),可被廣泛使用于制造、科技的硬質(zhì)泡沫塑料吸水率測試。
Product introduction:
一,It is designed and manufactured according to ** standard GB8810-2005 "Determination of Rigid Foam Plastic Water Absorption". It has the characteristics of simple use and high degree of hardness, and can be widely used in manufacturing and technological rigid foam plastic water absorption test.
二、系統(tǒng)組成:
硬質(zhì)泡沫塑料吸水率測試系統(tǒng)是由:硬質(zhì)泡沫塑料吸水率測試計(jì)算軟件、試樣裝載專用網(wǎng)籠、測試樣品水箱、硬質(zhì)泡沫塑料質(zhì)量測量儀、試樣專用切片器、玻璃載片等六大部分組成。
Second, the system composition:
Rigid foam plastic water absorption test system consists of: rigid foam plastic water absorption test calculation software, sample loading special cage, test sample water tank, rigid foam quality measuring instrument, sample special slicer, glass slide, etc. Six major parts are composed.
三、技術(shù)參數(shù):
★稱量范圍:5000g 測量精度:0.01g
★溢流箱規(guī)格:φ200*215mm
★網(wǎng)籠尺寸:Φ200*250mm
★電壓:200V
★外形尺寸:1000*600*800mm
★切片厚度0.1-0.4mm可調(diào)
★泡孔φ測試儀:小計(jì)算孔徑:0.1mm
Third, the technical parameters:
★ Weighing range: 5000g Measurement accuracy: 0.01g
★ Overflow box specifications: φ200 * 215mm
★ Cage size: Φ200 * 250mm
★ Voltage: 200V
★ Dimensions: 1000 * 600 * 800mm
★ Slice thickness is adjustable from 0.1-0.4mm
★ Cell φ tester: Small calculation aperture: 0.1mm
四、使用方法:
★被測物尺寸:長度 150MM、寬度150mm、厚度 75mm;休積大于500cm3;
★環(huán)境溫度:23±2℃ 環(huán)境濕度:50±5﹪
★泡水液:蒸餾后至少放置 48小時(shí)的蒸餾水;
★將硬質(zhì)泡沫切割成長 150MM寬 150毫米厚 75mm的正方形被測物。
★將試樣放于天平上,稱量干燥后的試樣重量(m1),準(zhǔn)確至 0.1g,并記錄。
★懸掛網(wǎng)籠浸入蒸餾水中,除去懸掛網(wǎng)籠表層氣泡,掛于天平的下稱鉤上,稱其表現(xiàn)重量(m2),準(zhǔn)確至 0.1g,并記錄下來,記住后將懸掛網(wǎng)籠取下。
★將懸掛網(wǎng)籠2邊套筒上的2個(gè)固定螺釘分別擰松,再將試樣安放圓盤上并居中;將壓棒下調(diào)壓住試樣,壓棒2端緊扣試樣,并旋緊2邊套筒上的兩個(gè)固定螺釘。
★將安裝好試樣的懸掛網(wǎng)籠重新浸入蒸餾水中,用軟毛刷跟攪拌除去懸掛網(wǎng)籠和硬質(zhì)泡沫表層氣泡。
★浸泡96小時(shí)后,將盛有試樣的懸掛網(wǎng)籠掛于天平下稱鉤上,稱量其表現(xiàn)質(zhì)量(m3),準(zhǔn)確至0.1g,并記住下來 。
Fourth, use method:
★ Dimensions of the tested object: length 150MM, width 150mm, thickness 75mm; rest volume is greater than 500cm3;
★ Ambient temperature: 23 ± 2 ℃ Ambient humidity: 50 ± 5 ﹪
★ Soaking water: Leave distilled water for at least 48 hours after distillation;
★ Cut rigid foam into 150mm wide, 150mm thick and 75mm square test objects.
★ Put the sample on the balance, weigh the dried sample weight (m1), accurate to 0.1g, and record.
★ The hanging net cage is immersed in distilled water to remove the air bubbles on the surface of the hanging net cage. It is hung on the scale's lower hook, and its performance weight (m2) is accurate to 0.1g. .
★ Unscrew the two fixing screws on the two sleeves of the hanging cage, and then place the sample on the disc and center it; lower the pressure bar to hold the sample down, fasten the sample at the two ends of the pressure bar, and turn Tighten the two fixing screws on the 2-side sleeve.
★ Re-immerse the hanging net cage with the sample in distilled water, and use a soft brush to stir to remove the hanging net cage and rigid foam surface bubbles.
★ After soaking for 96 hours, hang the hanging cage containing the sample on the scale's lower weighing hook, and weigh the performance quality (m3) to the nearest 0.1 g and remember it.
硬質(zhì)泡沫吸水率測定儀切片器使用說明

硬質(zhì)泡沫試樣切片器是硬質(zhì)泡沫塑料吸水率的一部分。
硬質(zhì)泡沫試樣切片器其主要結(jié)構(gòu)有樣品安放槽,樣品厚度調(diào)節(jié)器,樣品加緊螺絲,樣品放置調(diào)節(jié)器的作用是:安放樣品,并調(diào)節(jié)樣品切片厚度。
Instructions for use of rigid foam water absorber slicer
The rigid foam sample slicer is part of the water absorption of rigid foam.
The main structure of the rigid foam sample slicer is a sample placement slot, a sample thickness adjuster, a sample tightening screw, and the sample placement adjuster's role is to place the sample and adjust the sample slice thickness.
?切片器技術(shù)參數(shù):
1,切片器*小切片厚度:0.01-0.04mm,
2,試樣尺寸:50*50*100mm
3,外形尺寸:150*150*130mm,
4,有效行程:25mm
5,整體重量:11KG
? Slicer technical parameters:
1. Slicer * Small slice thickness: 0.01-0.04mm,
2. Sample size: 50 * 50 * 100mm
3. Overall dimensions: 150 * 150 * 130mm,
4. Effective stroke: 25mm
5. Overall weight: 11KG
?使用方法:
1,將試件厚度調(diào)節(jié)器調(diào)節(jié)到25mm刻度處,松開樣品加緊螺絲,將試件尺寸為50*50的樣件放入安放槽內(nèi),旋緊樣品夾緊螺絲壓緊試件。
2,用切片刀沿切樣器平臺(tái)表面將多余的樣品切除,為確保樣品上部平整,可用切片厚度調(diào)節(jié)器調(diào)節(jié)出0.3mm,用切片刀將樣品齊邊。
3切片厚度調(diào)節(jié)器調(diào)節(jié)出所需切片厚度(順時(shí)針為擠出樣品,逆時(shí)針為樣品退回樣品安放槽),但應(yīng)加上刀刃的厚度,切片刀刃厚度約為0.15-0.2mm,例如:切0.1mm厚度時(shí)應(yīng)旋出0.3mm左右,再用切片機(jī)進(jìn)行切片。
? How to use:
1. Adjust the thickness adjuster of the test piece to the scale of 25mm, loosen the sample tightening screw, place the sample with the size of 50 * 50 in the mounting slot, and tighten the sample clamping screw to compress the test piece.
2. Use a slicing knife to cut off the excess sample along the surface of the sampler platform. In order to ensure that the upper part of the sample is flat, use a slice thickness adjuster to adjust 0.3mm, and use the slicing knife to align the sample to the side.
3 The slice thickness adjuster adjusts the required slice thickness (clockwise for the extruded sample and counterclockwise for the sample returned to the sample placement slot), but the thickness of the blade should be added. The thickness of the slice blade is about 0.15-0.2mm, for example: cut When the thickness is 0.1mm, it should be turned out about 0.3mm, and then sliced with a microtome.